射頻導納液位計量程校正指導
射頻導納液位計廣泛適用(yong)(yong)各行業中液體、顆粒(li)和塊狀物料(liao)倉料(liao)位的連續測量。適用(yong)(yong)于(yu)(yu)在高溫(wen)、高壓力(li)、強腐(fu)蝕、強粘附、強沖擊(ji)、強磨(mo)損(sun)、粉塵大的環境下進行測量,有其它類型(xing)的物位計的性價比(bi)。產品應(ying)用(yong)(yong)于(yu)(yu)工礦現場(chang)(chang),適用(yong)(yong)于(yu)(yu)大多數(shu)應(ying)用(yong)(yong)場(chang)(chang)合,儀表由一個電路單元一套防(fang)爆外(wai)殼和桿(gan)式或(huo)纜式傳感元件組成,傳感器有多種型(xing)號可選,儀表可選整體或(huo)分體安(an)裝。
射頻導納液位計量程校正:
1.固定好液(ye)位計(ji),并鎖緊(jin)安裝螺栓(shuan)或(huo)擰緊(jin)卡箍;
2.任取兩不同的液位高(gao)度作為“低點校正(zheng)"及“高(gao)點校正(zheng)"點;
3.液位(wei)處于“低位(wei)校正(zheng)"點時(shi),同時(shi)按(an)下“M3+“S"鍵(jian)(jian)(jian)約(yue)3秒(miao),或長按(an)“Z"鍵(jian)(jian)(jian),顯示(shi)“00000",繼續按(an)“Z"鍵(jian)(jian)(jian)(移(yi)位(wei)鍵(jian)(jian)(jian))至右面“0"閃爍,再(zai)按(an)“S"鍵(jian)(jian)(jian)(增加(jia)鍵(jian)(jian)(jian)),修改為“9",按(an)下“M"鍵(jian)(jian)(jian)(確認鍵(jian)(jian)(jian))后顯示(shi)“000000"。通(tong)過“S"鍵(jian)(jian)(jian)(增加(jia)鍵(jian)(jian)(jian))及“Z"鍵(jian)(jian)(jian)(移(yi)位(wei)鍵(jian)(jian)(jian)),修改顯示(shi)與此(ci)時(shi)實際液位(wei)一致。按(an)下“M"鍵(jian)(jian)(jian),低位(wei)校正(zheng)完成。
4.液位處千“高點校正“點時,長按“Z"鍵(jian),顯示“00000",修改為“00010",按上述方法對高點作樣正。
虹潤儀表可(ke)以(yi)為您提(ti)供專業的射頻導納液位計選型建議和可(ke)靠的射頻導納液位計產(chan)品,有(you)任何疑問可以(yi)致電,我們會有(you)專業的技術人員幫您(nin)解答,希望能帶給您(nin)幫助!